Mdt 2012 osdcomputername variables

5. 48 thoughts on “ MDT 2012 Settings for fully automated LTI deployment, Part II: Customsettings. Les applications classiques sont des software basique qui s'installent au lancement d'un executable ou d'un fichier script (les scripts peuvent par exemple nous permettre d’ajouter une clé de registre manuellement en même temps que l’application s’installle ou d'ajouter des paramètres à un exécutable), tandis que les applications groupées contiennent plusieurs applications classiques. If the deployment fails before a partition has been created, you will find the log files in: Dec 08, 2016 · RECENT BLOG POSTS. I need machine to join domain using Dell service tag preferably, or if not, be prompted to supply this name. I would suggest checking the log files. 2 Mar 2017 Easy - use the OSDComputerName variable with a value of %SerialNumber% (or was it that easy?) Problem Statement How does the %  24 Jan 2016 Okay, we're breaking down the process of MDT 2013 Update 2 task sequence. If you install MDT 2012 and configure integration with SCCM, you will have a new setting to set the scratch space when creating an MDT boot image. In SCCM 2007 and 2012, you can actually make your task sequence prompt for this variable. Nov 07, 2016 · When deploying machines with MDT, unlike when using ConfigMgr, the task sequence does not suppress group policy processing, and sometimes you have group policies (admin account renames, or company policy notifications), that simply breaks the MDT task sequence. At the moment I can see test machine joins domain with auto generated name only. 1. this seamed like the perfect reason to start getting to grips with PowerCLI. g. In the Configuration Manager console, navigate to Assets and Compliance/Device Collections. If a valid name cannot be determined, it prompts We are using SCCM CB Build 1710, and during an OSD to Unknown Computers, we capture the "OSDComputerName" - for example DEDS1234. You will see that MDT 2012 can be tweaked in order to fit your situation. Our computer naming standards are "location-role-number" where the role is a 2 letter variable like WB for web server. Use the browser Find function (typically CTRL + F) to find a specific variable. Relevant to: SCCM 2007 and 2012 (including R2 and R3 versions), MDT 2013 SCCM and MDT offer a great deal of variables, but the documentation of them is sometime not so friendly. Exactly the same issue. Value is the text box at the bottom of my form that holds the complete computer name: We are using Windows 2012, with MDT 2013 I'm struggling to understand the property and variables in the CS. Instead of allowing your MDT Server to start selling meth, maybe theres a different way of fixing the problem. exe" application, because the script displays a prompt that needs to be visible to the user MDT 2010/2012/2013 variables are SCCM Task Sequence the variables that are gathered by MDT’s ZTIGather process and are documented in “Toolkit Reference. It simply just a text file in a folder (Package). nl/2012/11/sccm-osd-dynamic-computer-naming-  30 Dec 2015 You can build the server with either Windows Server 2012 R2 or 2016 to the native OSDComputerName variable that MDT will use to name  11 Mar 2015 Variable, Class, Description, SCCM 2007, SCCM 2012 computer name in the new operating system, use the OSDComputerName variable. Microsoft Scripting Guy, Ed Wilson, is here. If not, it sets SkipWizard=NO. Orchestrator is a feature in System Center 2012. 3. To change the computer name in the new operating system, use the OSDComputerName variable. One is called oEnvironment. Let’s learn How To Deploy Windows 10 Image Using Microsoft Deployment Toolkit (MDT) and the same image can be used in SCCM or MECM. SCCM 2012: Simple HTA Boot Menu Solution to set Task Sequence Variables. Aug 26, 2015 · i have 5 task sequences - W7 (x86 and x64), W8. Oct 02, 2013 · Obtain serviceUI. The customer asked me to add computers to SCCM using a continuous number, but during the deployment the computers must be renamed to identify if it’s a laptop or a desktop. Has anyone done this? I can do it in a vb script, just trying to port this to autoit so I can have more functionality. ps1 and store it in I've tried running a powershell script in both SCCM 2012 SP1 and SCCM  2 Mar 2018 Option 1 – SCCM Collection Variable SYNOPSIS Displays a gui prompt for a computername usable in a SCCM OSD Task Sequence. The sixth, and last step, is to create task sequence variables for the applications that have to be installed during the OS deployment. ini file for one touch deployments - gist:9fee58a6510e64607111 Oct 03, 2018 · I ended up making a script that dumps all task sequence variables and their values to a CSV. log in regular SCCM/MDT log path. . Apr 15, 2014 · Use the version of DISM that comes with System Center 2012 R2 Configuration Manager, the correct version is included in ADK 8. [ Default] OSDComputerName=DNK-%ComputerTypeName%-% ComputerSerialNumber% SCCM 2012 R2: Where is the SMSTS. We utilize MDT 2012 update 1 to deploy Windows 7 Enterprise x64 onto our PCs. 20 Apr 2015 will simply write the OSDComputername variable to the registry in WinPE I haven't tested it with MDT 2012 but I cannot see why it shouldn't  6 Aug 2014 If you are using System Center 2012 R2 Configuration Manager Using the OSDComputerName variable on the All Unknown Text #Send Computer Name to SCCM TS $tsenv = New-Object -ComObject Microsoft. double click on OSDComputerName, the following should appear. Following up on my promise and continuing this mini-series of blog post, where I’m trying to address some of the basics of Configuration Manager. ini I have customsettings. To start the correct version of DISM locate it in your start menu and right click on the Deployment Imaging Tools and Environment cmd prompt, choose Run as Administrator Jun 21, 2011 · Problem: I configured a task sequence to begin deployment of Windows 7 via USB thumb drives which are given to the techs. etc”, May 06, 2019 · The steps covered in this post applies to Configuration Manager 2012 R2 and above. For simplicity and because we will use network deployments, our deployment share will be installed on a machine running Windows Server 2012. Jan 13, 2017 · The Microsoft Deployment Toolkit offers advanced settings that allow you to automate the deployment process--and the CustomSettings. The task sequence was originally created as MDT Task Sequence but has been highly customized. 29 Apr 2013 by setting OSDComputerName using the Set Task Sequence Variable http:// itx-solutions. Oct 07, 2014 · It checks if the computer exists in MDT. exe. log located? Manager 2012 by using the OSDComputerName variable you first But in SCCM 2012 i only get name like minint-ABC123 have you an  17 Jun 2011 I've updated this post on 1 April 2012 as the screenshots shows the type Computername Laptop then enter the variable OSDComputername  3 Jun 2013 We begin with populating two variables, $ComputerModel and Save the above script to a . I wanted them to be able to install optional software at the time of deployment. Apr 15, 2014 · We are working on deploying Server 2012 R2 via SCCM with Roles being installed based on the computer name. this variable is used to tell the task sequence which drivers to inject based on a WMIC query of the computer. That should be enough to get it working without any MDT integration. We will create boot image in SCCM 1902 using the MDT Dec 01, 2015 · This system requires you to name your computers with a three letter prefix that is associated to the proper OU. First open the properties for the All Unknown Computers Device Collection in SCCM, and add a Collection Variable called OSDComputerName with a blank value. binding the devices to specific locations, running a particular child task sequence). MDT注入驱动程序仍然不会在PE中启动networking; 将驱动程序添加到MDT 2012部署共享; 在哪里可以findpython结构设置的例子? 如何轻松地通过gpo部署MS修补程序KB959628 exe / msp? Rails,Capistrano,Nginx,Unicorn – 应用程序已经被初始化(RuntimeError) 将文件部署到多个服务器 I would like to share an exciting announcement about the release of new MDT 2013 Update 1 from MDT engineering team site. Oct 08, 2010 · The script has been written to work with MDT 2010/MDT 2010 Update 1. Reason for asking, i do not have the MDT DB. SCCM and MDT offer a great deal of variables, but the documentation of them is sometime not so friendly. ini. The location variable is used throughout the task sequence for decision making similar to the naming convention (e. That binary is available with MDT 2012 (you’d need to install MDT first). With this setup. MDT 2012: Capturing a Reference Image - Part II. The second step we use to define the MigData variable. What I would like to do further down the task sequence is use this same variable, in order to apply an oprating system with defined language pack (We have a single OS built, but an unattended. At one of my customers I was responsible for deploying computers using SCCM 2007 R2. exe from the installation media. ini as below, but however the settings are not doing quite what expected when selecting the TS. Feb 16, 2013 · SCCM 2012 R2 Part 12 C OSD Deployment and Task Sequence - Duration: 48:32. com™© Le lab • Pour cette formation, je vais utiliser Windows 10 et Hyper-V • Vous pouvez aussi utiliser : Hyper-V Serveur (2012 R2 en GUI) Nano Serveur (il faudra un second poste) vSphere 6 (il faudra un second poste) XenServer 6 (il faudra un second poste 12 Apr 2013 Set computer Name using OSDComputerName variable. To achieve this I use the following code snippet: SCCM 2012 – Deploy multiple applications using Dynamic Variables in Task Sequence Description A key requirement while deploying OSD based task sequences is to deploy applications after the image is deployed. 4 Feb 2015 Members of the All Unknown Computers collection in SCCM 2012 Creating the OSDComputerName variable for Unknown Computers. This reads a few WMI properties and concatenates the new name and stores it in OSDCOMPUTERNAME variable for later use. The other variable which is called SBComputerName. The other deployment solution Microsoft has, System Center 2012 Configuration Manager, will not […] Jan 31, 2014 · The reason for a custom script, is that the customer wanted to see a prompt displaying how large the backup . Using TCP/IP or Named Pipes to Access the MDT DB While accessing the MDT database with Windows PE, you cannot use integrated security using an Active Directory username and password if you are connecting to the database using TCP/IP. Posted on January 23, 2013 by Håvard If you for some reason are not able to use MDT and the UDI wizard, you may want to create a HTA Application to handle roles or special choises during deployment. Enter the "Convert-CMApptoMDTApp" PowerShell script. In this post I describe how to move an existing computer account to a dynamically computed OU during OSD using Maik Koster's web service. The script was used in an SCCM 2012/MDT 2012U1 UDI Task Sequence. This feature enables software to be automatically (re-)installed during a refresh scenario task sequence if it is installed in the current OS instance/installation. Set It Up. ini works together, We need to have the ability to deploy 2 different images and able to capture, i have tried to build the CS. exe" application, because the script displays a prompt that needs to be visible to the user The Variables are set using a FrontEnd or Collection Variables. The functionality of this script is very simple, it will define the task sequence variable ‘MachineObjectOU’ based on the OSDComputerName variable using If, ElseIf and Else statements. com/en-us/sccm/core/ understand/find-help#send-a-suggestion for an explanation of . I kicked off the script using a "Run a Command Line" step and used the "ServiceUI. Jul 06, 2017 · MDT 2013 Variables; MDT 2013 Variables. INI (Rules) to call an external script to populate the OSDComputerName variable. This week, Windows PowerShell MVP, Sean Kearney, is our guest blogger, and he is writing about Microsoft Development Kit Update 1 (MDT). com Aug 19, 2012 · Windows 8 RTM is now available and so is the deployment solution to deploy it. The computer name variable is actually stored in a simple task sequence variable called OSDCOMPUTERNAME. In essence, the actual join domain process occurs in the Install phase and requires a handful of administratively assigned settings to succeed. See full list on deploymentbunny. A few more searches and I found this blog site here. In my company, I work with the latest. This was easy enough but Microsoft has made it even easier. 1 (x86 and x64) and server 2012 R2. If this variable is not specified prior to displaying this page, the value of this variable is set to Pending. However, as I discovered in my last project (SCCM 2012 integrated with MDT 2012), if the computer being deployed with an OS already exists in Active Directory, it won't be moved to the computed OU. Jan 31, 2014 · The reason for a custom script, is that the customer wanted to see a prompt displaying how large the backup . Side question - with the cumulative updates for Windows 10, is it best to replace the package in MDT with the full latest CU, or can I get away with adding the May 04, 2010 · Tip: You can find more information about automating LTI deployment in the Windows 7 Resource Kit from Microsoft Press. The easiest way to get the additional variables offered by MDT 2010/2012/2013 is to configure MDT integration for SCCM, and use the MDT Jul 05, 2013 · In the function above, I am assigning my computer name to two different variables. The article on task sequence steps includes the list of variables specific to each step. My main issue is finding actual reference material for the MDT task sequence templates when integrated with SCCM. Jun 25, 2019 · I have a set of collections with collection variables assigned to them. The IsOnBattery variable is set by the MDT Gather step. line[1] = line1. for hostname to match asset… The Lite Touch wizard will set the same task sequence variables in either case, and the "Recover from domain" step will notice that the unattend. sccm task sequence prompt for ou Getting MDT wizard prompts despite customsettings. Sep 11, 2017 · I work with a lot of Microsoft products, one of my favorite is Microsoft Deployment Toolkit and System Center Configuration Manager, otherwise known as MDT and SCCM (Sick-em boy). By default, MDT 2012 allows you to define some rules in order to  1 Apr 2020 To change the computer name in the new OS, use the OSDComputerName variable. We are ready to click Next now. I will describe the steps needed for that here. I have created some tables below of the variables, which are a little easier to filter, sort and generally find the variable you are after. We take the ServerA value and create the path with the built-in OSDComputerName variable available to the Task Sequence. be Set computer Name using OSDComputerName variable Common Scenarios. ini file lets you take that automation a step further. Use collection variables in SCCM 2007/2012 UDI Deployments Integrating the Microsoft Deployment Toolkit (MDT) with SCCM opens up many possibilities. 这导致了我的脚本中没有正确访问新variables的错误 ; 我现在有我的代码工作。 它从HTML中提取数据并设置OSDComputername环境variables。 我更新了下面的代码来匹配工作代码。 它是正确的发射和设置我的电脑名称和描述完全符合我的意愿。 问题解决了! HTML页面: Test 4 – Set Task Sequence Variables OSDComputername to CON-LAB1 and JoinWorkGroup to Continuum then run script without supplying parameters Expected results: Computer and should be renamed and new workgroup joined. If the computer exists in MDT, it grabs the Roles. MIG file would be before initiating the backup. Jun 16, 2015 · This procedure requires MDT-integrated ConfigMgr 2012, and also requires Windows PowerShell to be added to your boot image. Jan 18, 2017 · When you are a frequent user of SCCM, sooner or later you will want a custom variable on which u can set a dependency for jobs further on in the task sequence. 14 They were using the build-in UDI Wizard, that comes with the Microsoft Deployment Toolkit (MDT). Stores and specifies the computer name. They are read only variables. It also dumps all TS variables before, and after setting the MachineObjectOU variable to a file named ZTIVariablesExport. 30 Jan 2014 I tested it using SCCM 2012R2 integrated with MDT2013, but I can't see for input during a task sequence, and sets the input as a TS variable. He wanted to know where he could find a list of all the Time Zones Names, so he could change the default “Pacific Standard Time” to something else. Set one or more task sequence variables on the collection. In order for the PowerShell script to be visible during a Task Sequence, we need to launch it with the help of a file called serviceUI. dat file (that is the file storing all the current properties to survive reboots) it’s recommend deleting this folder every time before you run a test to avoid side-effects. exe from MDT. Variable, Class, Description, SCCM 2007, SCCM 2012 To change the computer name in the new operating system, use the OSDComputerName variable. The Microsoft Deployment Toolkit (MDT) 2013 Update 1 released on August 17, 2015 and is now available for download from the Microsoft Download Center. Hi, I have a quistion. For example, if a runbook has an input parameter named OSDComputerName, then the OSDComputerName task sequence variable value is passed to the runbook. It locates at about line 911 in the script. Aug 05, 2011 · The MDT Deployment Database provided with MDT 2010/2012 on the surface looks very simple – but is actually very powerful. This weekend, I was speaking about blogging and technical writing at the South Carolina Writers Workshop in Rock Hill, Apr 27, 2017 · Getting your operating system deployment one step closer to being zero touch is always a good goal, so with that in mind here is how to automatically enable BitLocker during OSD using a PIN that you define in a variable at the beginning of the Task Sequence. Link HERE, scroll down to the FrontEnd Link. This task sequence step installs an operating system on the target computer. My favorite part is customizing the Windows Operating System. SCCM 2012: VBScript to list out Task Sequence variables. 1, Windows 8, Windows 7, Windows Server 2012 R2, Windows Server 2012, and Windows Server 2008 R2 using: setup. In our task sequence we have added the following condition on the IIS role install If ALL conditions are true: I use the MDT variable IsLaptop as an option on my Task Sequence step. Nov 10, 2014 · Hi, I’m looking for the same functionality as using blank collection variables (prompting at TS execution), except per task sequence. If it isn't, the PC is set to run a UI similar to the one that @Arthur posted about, UI++. Step 4. each task sequence has the "set task sequence variable" added. If you are using MDT 2012 Update 1, you will be able to use transparently your powershell script within your task sequence. 16384. jpg That relies on the PC being in SCCM already. Within the SCCM task sequence, after the Gather step, the serialnumber, IsLaptop and IsDesktop variables are populated and available. Jan 02, 2020 · This allowed the variables I was getting to be posted into the BDD. out The Deployment Bunny's blog Modelalias User Exit for Microsoft Deployment Toolkit 2010/2012. This Deployment Share is the home of our applications This sets the variables Unit and Location variables based on the selected choice and sets the OSDComputerName. vbs files from a MDT 2010 installation into a package. One of the more interesting ones is the use of User Driven Installation (UDI) task sequences. Recently i needed to build a lab environment, nothing new in that but this time there was a fair chance that once it was built i would have to tear it back down and do it again and again. This script was designed to get the current or old computer name from WinPE and apply it to the Task Sequence Variable OSDComputerName. Solution: UPDATED HTA FILE TO LATEST VERSION Using Groups within the Task Sequences assigned variables gave me the best […] Jan 04, 2017 · Update: Added optional script that uses the HP Ownership Tag How to use: Create a package for the script. ps1 * make sure you link an empty package (an application package with no program) to the OSDComputername. ini file and putting them in as Task Sequence variables at the very beginning of my TS, but no joy. OSDComputerName=computer name in database. At this point, I’m sure we’ve all read and re-read Gary Blok’s Waas posts and picked up a few tricks, I know Sep 09, 2013 · Im trying to read a custom task sequence variable in a SCCM 2012 task sequence. The best way to work around that is to use a staging OU. It has been written in VBScript to not require PowerShell in the boot image. But whereRead More Oct 11, 2011 · The one I've used before is the ConfigMgr/MDT method, which asks the computername before deployment (manually) and uses this name during OS deployment. 27 Apr 2017 You may already use the OSDComputerName variable in which case you will already be familiar with this! Double click on OSDBitlockerPIN  I rechecked and I am actually setting OSDComputerName as a collection variable SCCM 2012 - Deploy multiple applications using Dynamic Variables in Task  I checked “Save path as a variable” and chose “MDTLite” as the variable Windows 7 could be deployed straight into Audit Mode using MDT 2012 in my Lab. They also require that the boot wim used has the PowerShell AD Module copied to it so it can be imported before running the scripts. When I launch a deployment the fields are all pre-populated with data (time zone, language etc. Using SCCM 2012 SP1 with MDT 2012 integration this was easily achieved using the MDT task sequence variables. Here’s what I mean: [Settings] Priority=IsVM,IsLaptop,IsDesktop,IsServer,SetComputerName,Default Properties=ComputerType,MyCustomProperty Notice above that in my [Settings] section, the Priority header is set to “IsVM, IsLaptop…. 'Set the OSDComputerName variable to the detected name assuming this is a known computer. just make sure you load the MDT toolpackage Before the passwordprompt. Add two custom lines under the PSDistrict_ variables in the main script region . This can be useful (and necessary) when performing activities like flashing the BIOS, running the new MBR2GPT utility, or upgrading to a newer version of Windows. In this database we can store all of the variables that we used in the MDT Lite Touch world as well as extra OSD based variables for use in Zero Touch and server build task sequences. Open the Properties tab on the All Unknown Computers collection and select Collection Variables. All the _SMS* variables are read only built in SCCM Task sequence variables. Every time I read a new post blog about things people have done with their Task Sequences, I get inspired to try more things. This script converts applications created in ConfigMgr 2012 SP1 to MDT applications. I use the Now Micro front end in my lab. MDT uses setup. Stores the name of the computer that the task sequence will use to log all status messages. ), however, I still have to click next through each o The complete variables used and accessible by SCCM during the task sequence can be found here: SCCM 2012 and above click here; SCCM 2007 click here ; Side note : All variables can be read and written except the ones starting with “_” (Underscore). MDT 2012 PART VIII – Automatically Set computer Name C-nergy. ini file is generated automatically when you create a new MDT Task Sequence. Before proceeding by click on Next, click on Edit and for testing purpose I am providing value Win10-Prompt. The MDT documentation has a lot of information on variables and task sequences Nov 21, 2013 · Then I added a step, prior to running the script, to set OSDComputerName to %_smstsmachinename% if OSDComputerName doesn’t already exist, and then use %OSDComputerName% instead of %_smstsmachinename% in all instances. Windows 10/SCCM 2012 R2 (1511)yes there is a later one. Jun 14, 2017 · I've tried removing those settings from my CustomSettings. ps1 will need to be updated in order to read and write the custom TS variables that we created. Scripts for managing and deploying with the Microsoft Deployment Toolkit - aaronparker/MDT Dec 12, 2010 · At last you can use the build-in scripts that's included with MDT, for using in ConfigMgr 2007 Task sequences. I’ve tested on Windows 7 but should also work with Windows 8. 62 thoughts on “ MDT – Put the domain join where it belongs. Click new and type OSDComputerName. It does this by mapping the software listed in Add/Remove Programs on the existing OS installation (by querying ConfigMgr’s hardware Dec 23, 2019 · This post will help you to manage the deployment of Windows Captured Image & Deploy Windows Image using MDT + SCCM. Oct 12, 2012 · I like to use the MDT 2012 Update 1 database to store data to configure my servers, a lot of data can be hold in this database to customize and automate your deployment with MDT 2012 and with each release Microsoft adds more possible features and functions to this database. In the Task Sequence after initial format of the drive create a Run Command Line step using the package that you created Aug 09, 2016 · The New-OSDTattoo. May 23, 2012 · Hi SQL'ers, I've put this question in the MDT forum first, but thus far nobody has answered yet, so since it has to do with SQL i thought maybe i can try here:) I've followed Rename computername during SCCM Tasksequence . Aug 25, 2013 · Using PowerShell to set OSD task sequence variables August 25, 2013 3 comments For a few months now I have been trying to work out running a simple PowerShell script to set some task sequence variables in my build and capture task sequence. This article is a reference for all of the available variables in alphabetical order. xml didn't do the join. click next and the task sequence completes as normal. Jun 03, 2013 · Hi Nikolaj, I was able to follow your instructions and was able to get the OSDComputerName to change and apply the name to clients OS. The file located in the following path: C:\Program Files\Microsoft Deployment Toolkit\Templates\Distribution\Tools\X- Your Architecture (be sure to run it with the correct Boot Image architecture). ini for MDT but 2012 -2012. Jun 26, 2015 · The scripts are dependant on two collection variables: AssignedUser, and OUName, and the TS variable OSDComputerName. My favorite, which works with an MDT integrated task sequence, is to assign a collection variable to the All Unknown Computers collection. 21 Oct 2016 MDT 2010/2012/2013 variables are SCCM Task Sequence the 1) Make up your CSV which contains MAC, ComputerName, Variable Value. For the computername the MDT variable is OSDComputername Turns out that the name of my Section headers cannot be the same as that of the built-in MDT variables. The variable notes if it's specific to particular step. It Apr 19, 2017 · In this blog post, I am going to show some simple steps that you can add to your Task Sequences to be able to detect, disable, and enable BitLocker status. log" files, which made it easy to see what variables I was getting. We are reimaging Operating systems wirelessly and one of the problems we've run into is that when assigning the computer name the computer cannot connect to AD to query the %computername% variable so it assigns it a random Mini-xxxx name. After deployed the task sequence to the test computer, we can see the variables are written into the Registry. One of those things is setting Task Sequence variable values from the output of a script. vbs UEFI The functionality of this script is very simple, it will define the task sequence variable ‘MachineObjectOU’ based on the OSDComputerName variable using If, ElseIf and Else statements. GitHub Gist: instantly share code, notes, and snippets. After searching online for a while an… 70-243: Administering and Deploying System Center 2012 Configuration Manager 70-410: Installing and Configuring Windows Server 2012 70-411: Administering Windows Server 2012 70-412: Configuring Advanced Windows Server 2012 Services MCSA: Windows Server 2012 70-533: Implementing Microsoft Azure Infrastructure Solutions Dec 06, 2012 · Thursday, 6 December 2012 How to prompt for computer name in MDT/SCCM Task Sequence (OSD) I was using Collection Variables in Collection Settings to ask Computer Name [OSDComputerName] at the beginning of my OSD Task Sequences. In this part I will demonstrate how to use the Webservice via a PowerShell script to securely move a computer object during the operating system deployment (OSD) task sequence using Microsoft Deployment Toolkit (MDT). The AD OU is a direct relation to the "Branch" Chosen and auto populated. 14 Aug 2012 However, as I discovered in my last project (SCCM 2012 integrated with MDT The value of the OSDComputerName variable will have been  17 Dec 2009 TSEnvironment"). Which means they would wipe and load an entire lab remotely and still have to run up to that lab a few hours later to manually name each machine and join it to the domain. type in a computername. Specifies the mode for configuring user affinity in Configuration Manager 2012. On the Install Software step you only want to install on Laptops, you add the “Option-Task Sequence Variable” IsLaptop equals TRUE Apr 24, 2013 · Traditionally VBscript has been “the” script type to use in OS Deployment scenarios, but with WinPE 4. CANADIAN Institute for Professional Studies 39,015 views In order to interact with the PowerShell from within the task sequence, you need to run it with a file called ServiceUI. In the past, I would use DISM with /Set-ScratchSpace:<<number>> to set it to 128MB. The first place you can do this is in the collection properties for where your deployment is pointed. Jun 28, 2019 · In Part 1 we walked through the installation and configuration of Deployment Webservices. Locations of MDT log files: Your logs will be in different locations depending on when the MDT Task fails. Nov 11, 2011 · I accomplished this using a series of powershell scripts and task sequence variables. but you can create your own package and reference that when you call the script. Partition if necessary – It checks for all the conditions if . During the MDT deployment task sequence, it joins our domain (using credentials that are prompted for from the tech that is imaging the computer during the gather phase) into an OU that has WSUS GPOs applied to automatically check for updates but do not download or Aug 14, 2017 · Today I got a call from a customer that was playing around with OSD in System Center Configuration Manager and the Microsoft Deployment Toolkit (MDT). Sep 29, 2016 · 29/09/2016 13 Formation MDT (Microsoft Deployment Toolkit) 2013 U2 alphorm. SCCM 2012 SP1 and MDT 2012 Task Sequence Templates&comma; MDT File&sol;Settings Packages. com Hi Mike, I’m currently working with SCCM R2. Example: ABC: _SMSTSMDataPath: Specifies the path defined by the SMSTSLocalDataDrive variable. Turns May 11, 2012 · now you will see a Task Sequence window called Edit Task Sequence Variables. 27 Oct 2014 Setting OSDComputerName using CustomSettings. vbs P Use this step in the task sequence to set one or more task sequence variables. The complete variables used and accessible by SCCM during the task sequence can be found here: SCCM 2012 and above click here; SCCM 2007 click here ; Side note : All variables can be read and written except the ones starting with “_” (Underscore). Going over each step within a standard client task sequence within MDT 2013 Update 2. This method is the traditional method used, initiated by running setup. Updating status to completed – see https://docs. exe -noprofile -file OSDComputerName. Click OK to exit the Properties window. Jun 23, 2020 · MDT can be installed on a client OS (Windows 7/8) or a server OS (Server 2008 and above). This is a pretty simple request however the main hurdle was dynamically setting part of the computer name as we use Location-Serial. MDT can deploy Windows 8. 10 Nov 2014 Use Collection variables to build dynamic Task Sequence in SCCM 2012. Introduction. Rename computername during SCCM Tasksequence . I have tried your solution here but at the end of the deployment the PC still with the generic MININT…name. You can specify dynamic names by using “roles” with the MDT database. In most cases the log files are required to investigate OSD failure. In my production environment, I have logic in the CustomSettings. The file is located in these locations, depending on the architecture: Jul 27, 2016 · PowerShell Concatenate New SCCM or MDT Computer Name Load script via Task Sequence in WinPE to automate the creation of a new unique computer name to assign to SCCM or MDT to rename the computer. This is commonly used to account for different geographical locations. add the MDT Gather step somewhere after the image has been deployed 2. domain. 0 in the ADK and MDT 2012 (u1) it is now an option in some scenarios. Make an existing MDT (2012 update 1) enviroment ready for Windows 10 September 6, 2016 March 15, 2017 Robin Leave a comment In this post, I will describe the steps needed to update a existing Microsoft Deployment Toolkit (MDT) 2012 environment to MDT 2013 Update 2. … Nov 12, 2015 · and click on Collection Variables tab. ini ” John 5 December 2013 at 17:14. We're setting up SCCM 2012 integrated with MDT 2012 for our OSD. Let’s go ! Set computer Name using OSDComputerName variable Common Scenarios. MDT customsettings. In Part 2 we walked through securing the Webservice. log and the "Script_Name. With MDT 2012 update1, you can now use Powershell script in order to automate a series of tasks. The issue I am running into, is after the machine reboots into the Operating System during the Task Sequence, I have a step that evaluates the OSDComputerName Variable and it appears that the variable is overwritten when the machine reboots in between tasks. Yes: Yes: _SMSTSMediaType: Built in: Specifies the type of media that is used to initiate the installation. ps1 file, name it OSDComputerName. [Settings] Priority=Default 06 / 12 / 2012 • by Osman Shener • MDT, OS Deployment (OSD), SCCM / Configuration Manager • 2 Yorum / Comments I was using Collection Variables in Collection Settings to ask Computer Name [OSDComputerName] at the beginning of my OSD Task Sequences. _SMSTSInWinPE = True – It means that PC is not in Full OS, but in WinPE stage. Mar 20, 2013 · Powershell (18) MDT (9) Active Directory (7) MDT 2012 (5) Microsoft Deployment Toolkit (5) PSexec (5) Primal Forms (4) Wake on LAN (4) Zerotouch deployment without SCCM (4) MDT Database Object Property (3) MDTDB powershell module (3) MDX (3) Michael Niehaus MDTDB module (3) PXE (3) MDT Property values (2) PowerShell array (2) Start LiteTouch In order to interact with the PowerShell from within the task sequence, you need to run it with a file called ServiceUI. Jan 07, 2019 · More PowerShell Variables; PowerShell’s $_ Variable. This then lead me to see that the user name and password that was being passed to the script looked like they were encrypted. MDT 2012 Update 1 contains a nice little and very easy to use feature known as Package Mapping. I have imported the Multi Language OEM DVD in MDT 2013 When I try to deploy an OS to a machine , it Always installed the English version of Windows 7 and I want it to install the Dutch Oct 08, 2013 · The problem is that you find lots of customsettings. Choose boot image: When prompted,choose custom image we captured from client Windows 10 computer. click ok and the computername value should be listed to the right of the variable name as shown below. Click the yellow star to add new variable. Use this variable to configure the behavior of creating affinity between the target computer and user accounts in the SMSTSUdaUsers task sequence variable. Oct 15, 2016 · There are countless ways to set a hostname in SCCM OSD Task Sequence: through variables, queries or manipulating various files. ini set to have most fields filled out except computer name and admin password. No need for MDT or anything. xml per language). Set the computer name as OSDComputername task sequence variable. exe by Oct 27, 2014 · The CustomSettings. exe (From MDT Toolkit) to the same folder. To work around this issue, disable the Computer page, and make sure that the OSDComputerName and OSDWorkgroupName variables are set. In these steps I assume you already created a MDT 2013 Task Sequence, a MDT 2013 package, and a Settings package as part of that process. EDIT: Formatting likes to use powershell commenting as headlines. If the computername not equals MININT and it has a OS-%, LT-% and a AP-% Role, it will popup a question like this: Dec 04, 2015 · You will now need to setup computer variables. As of this writing (August 19, 2012) MDT 2012 Update 1 is the only deployment solution by Microsoft that supports deploying the final version of Windows 8. collection. ini file. doc” that comes with the MDT 2010/2012/2013 install. This is my current setting UserDataLocation=AUTO UDShare=\\SHARE\MDT\USMT\Migdata UDDir=%OSDComputerName% ComputerBackupLocation=NETWORK BackupShare=\\SHARE\MDT\USMT\Backup BackupDir=%OSDComputerName% ScanStateArgs=/v:5 /o /c LoadStateArgs=/v:5 /c /lac MDT 2012 - pull computername from database not working So this mean MDT not pulling rules from database. It utilises the new Configuration Manager 2012 SP1 and MDT 2012 PowerShell modules. exe from MDT 2012 and create a package. By default, MDT 2012 allows you to define some rules in order to set the correct computer name during the deployment process. Click OK. CANADIAN Institute for Professional Studies 39,015 views Dec 11, 2017 · Step 6 – Create the Task Sequence Variables. For every application I create a task sequence variable named APPIdXX with the value of the application. It first collects several values (Make, Model, Serial, Name) then follows pre-set rules for naming conventions. Select 2-2 (1-1 is just 350 MB partition) Set parameters for domain join The %OSDComputerName% directory is an artifact caused by the fact that the property (or variable) OSDComputerName wasn’t set at the time the SLShareDynamicLogging property was processed in the CustomSettings. Enter OSDComputerName for the variable name. I believe that the copy-paste should also maintain the same variable for consistency, but if they happen to match then it’s less of a problem. Hi Rens, I’m just getting started with MDT/WDS and so far things are going okay but from what I’ve read on countless pages, there’s no real 1 way to do this… which can be frustrating for someone new! Jul 25, 2013 · Set OSDComputerName during MDT or SCCM Deployment with VBScript This is a simple script I wrote for programatically setting the OSDComputer name during a deployment (MDT or SCCM). Feb 14, 2017 · This post shows the steps to capture SCCM task sequence log files post OSD. I  17 Sep 2017 A MDT Toolkit package is available in Configuration Manager 5. During the MDT monitoring process the correct name appears but it does not match the machine. ini (1) Exclude Updates (1) IE8 (1) Lenovo (1) Litetouch (1) MDT Progress Bar (1) Mass Storage (1) OSDComputerName (1) Office 2007 (1) Post Application Install (1) SATA (1) Server Migration (1) Troubleshooting MDT 2010 (1) TsProgressUI (1) Windows Desktop Jun 25, 2013 · So, when the time comes to update your reference image, you need to create all of those applications again in MDT. 99% of these machines are all based in computer labs. First created a Non-mandatory advertisement on a OSD collection (in my case created as "Operating System Deployment"). Applies to the Set Dynamic Variables step. Heres 1 example, I work in education. Modify as needed We are using Windows 2012, with MDT 2013 I'm struggling to understand the property and variables in the CS. Item(“OSDComputerName”) and this variable is what MDT uses to name your computer after deployment. 4 Oct 2012 The problem with this is I would get "Undefined Variable" for OSDComputername and I am not sure it is pulling the data from the HTML correctly. If you want to use TCP/IP, you must define a local SQL user with a corresponding password. In MDT 2012 update 1 this was an issue: MDT 2012 settings per task sequence. And with new functionality in MDT 2010 Update 1 there is even more available! (User Driven Installation) MDT 2010 can be used for Lite Touch Installation (LTI): MDT 2012 New Feature: DaRT integration by Michael Niehaus Note that the DaRT Remote Connection tool is part of the Microsoft Diagnostics and Recovery Toolset, a core component of the Microsoft Desktop Optimization Pack (MDOP) available for customers with Software Assurance. MEMCM: Move Data Warehouse July 26, 2020; Making Microsoft Teams Your Own: The Secrets of Superusers Series, #3 July 23, 2020; Did you know: Microsoft originally communicated about an Updated Meeting join experience for users who don’t have a meeting creation policy assigned in MC209349 (April ’20) July 22, 2020 May 29, 2018 · This sets the variables Unit and Location variables based on the selected choice and sets the OSDComputerName. This time, I’m going to give you an example of how you can to add computers to groups in AD (Active Directory) during the deployment of Windows using a web service and Powershell. env("OSDComputerName")  2 Nov 2013 We can then leverage this variable to create a step in the task sequence to run of the %OSDComputerName% variable and displays a custom error message in order MSU) during OS deployment using MDT/SCCM2012. Common Scenarios. Mar 30, 2012 · To display a HTA in WinPE you need to have MDT integrated to you SCCM enviroment. I use a script for this which can be used to set the AD description using a variable like for instance a Computer or Collection variable that can be filled in during the deployment or a value from MDT variables if you like. MDT can pull in this information and toss it into the OSDComputerName variable to hasten your Deployment Wizard. Some Good Operating System Deployment References. As this folder also contains the variables. Still it's We are playing around with Task Sequence variables in SCCM 2012 Sp1. The size could be 32, 64, 128, 256, or 512. Feb 01, 2017 · This is no issue with ConfigMgr or MDT but creating an automatic way to do this remotely would be interesting. My current setup is running SCCM 1902 and I will be installing the latest version of MDT. 1 x64 Settings. If it’s not set, you’ll get the MININT-xxxxx name. When MDT is installed, a Deployment Share will be created. For instance the DeployWiz_ComputerName wizard allows you to fill some properties as Computer name or domain name. if OSDComputerName is set you should get that value. Verify that it worked Nov 07, 2013 · In a Computer Refresh scenario on an un-encrypted machine, the old Computer Name is stored in plain text in the registry on the local disk. Update your CustomSettings. Aug 27, 2018 · The more I dig in to SCCM/ConfigMgr, the more cool things I find. Marc 8 April 2015 at 21:01. I recommend using a stored procedure to get the next free number from a SQL database, and used that in the OSDComputername definition. If you want to use it in plain SCCM OSD deployments, just add this script and the ZTIDataAccess. 1 as it uses the same location for the default wallpaper. vbs and ZTIUtility. These properties will be stored in MDT using different variables. Test 5 – Remove all variables and test script without parameters. September 3, 2010 ConfigMgr , MDT 2010 , Microsoft , Microsoft Deployment Toolkit , Operating System Deployment , SCCM , Solution Accelerators , Systems Management , UDI No Comments Select this option to automatically provide the Orchestrator runbook input parameter values( which assumes that the runbook parameter values are task sequence variables). microsoft. powershell. ini to properly name the machine based on specific criteria so Jan 23, 2014 · OrchestratorIn System Center 2012, System Center 2012 SP1, and System Center 2012 R2, the Orchestrator component enables you to automate business processes and IT operations in your data center without scripting or programming. Mass importation of variables/computer creation is possible via the SCCM SDK, but that is a topic probably better left for another blog posting. _SMSTSMake. Nov 15, 2013 · On the Properties window, click on Collection Variables tab. In fact, when you add a step in your task sequence, you will see that you can simply specify powershell script option. i added the files to a folder called WNB and copied that to the script folder inside the MDT toolpackage source. This could be done via an MDT Database (thus getting pulled in via a Gather step) or in SCCM by a computer variable put directly on the computer. Here is a link: Generate computer names in MDT 2012/2013 based on prefix and a sequence number Mar 09, 2020 · As the OSDCOMPUTERNAME variable has been created and left empty, Task Sequence prompts for this variable under Edit Task Sequence Variables. SCCM MDT 2013 Windows 10 TS explained. See full list on potentengineer. 1 Sep 2018 If you want to give a computer name as part of the task sequence process, you need to create variable ties to the collection. When i configure TS Variable OSDComputername, MDT renames the computer but it does not keep the setting until the end of the build. In this example my settings package for ConfigMgr 2012 has its package source path on D:\SCCM_Sources\OSD\Settings\Windows 8. OSDComputerName: Netlogon Notepad++ Office 365 PowerCLI Powershell putty Robocopy S3 Server 2012 R2 slmgr. I am the lead author for this Resource Kit and I also maintain the Unofficial Support Site for the Windows 7 Resource Kit with answers to questions posted by readers, as well as links to the latest resources on Windows 7 deployment, administration and troubleshooting. Scenario: You would like to use a PowerShell script that uses properties from the ZTIGather process Solution: Create the script and save it… Dec 27, 2011 · Summary: Microsoft PowerShell MVP, Sean Kearney, shows how to use Windows PowerShell to work with the MDT CustomSettings. jpg The task sequence picks up those variables and automagically puts the PC into the correct OU when it's built. $TSEnv = New-Object -COMObject Microsoft. This is the script I use: Sep 01, 2018 · If you want to give a computer name as part of the task sequence process, you need to create variable ties to the collection. In the screenshot as well as the other two commands utilizing computer name, they use %OSDComputerName% instead. SMS. ps1 #3 Sep 12, 2013 · If you are using MDT integration, you can define the ServerA value dynamically using the Database. It also collects all TS-related logs, ZIPs them, and saves the ZIP file on a network folder and then emails me with the ZIP file attached with some basic info about the machine and deployment in the body of the email. Apr 20, 2015 · Displaying OSDComputername in MDT WinPE background picture By Jörgen Nilsson Configuration Manager 3 Comments One very appreciated feature in Configuration Manager 2012 when you integrate it with MDT is the background pictures showing OS deployment step, IP Address, MAC Address and so on to the end user och technician deploying the computer. I’m trying to setup a Computer name base of AD or Device Collection on SCCM. Now create Task Sequence: Software Library-Task Sequence-Create Task Sequence. _SMSTSMediaType != OEMMedia – It means that system does not have prestaged OS Oct 11, 2010 · MDT 2010 (8) MDT 2012 (3) MDT 2011 (2) Windows Updates (2) Change Log (1) CustomSettings. I am working towards ZTI (as far as possible) using MDT 2012 on a 2008 r2 box for migration from XP to W7 Pro sp1. Expected results: No changes should be made. Apr 22, 2016 · I always use a HTA (UI++) for my SCCM Task Sequences to fill a lot of variables at the start of the sequence, however i was recently asked to make a Zero Touch (ZTI) build for Windows 10 for a specific department. Jul 15, 2014 · Summary: Microsoft Scripting Guy, Ed Wilson, talks about several approaches for concatenating strings by using Windows PowerShell. You need something to tell what role a computer should be a member of. SCCM allows you to create custom Windows PE boot images using MDT that include extra components and features. You can automate hostname assignment and derive it from, for example, a serial number or a MAC address, however sometimes it is necessary to prompt user to enter hostname (e. If checks if the OSDComputerName equals MININT-% and if it has this name it sets SkipWizard=NO. Theres probably a dozen other ways to do this including using an MDT wizard. Jan 26, 2012 · It can in some scenarios be useful to set the computers AD description during SCCM OS deployment. Copy serviceUI. 3 Oct 2018 From there, I ran the following 2 commands to get the value of my OSDComputerName variable. If you need to run your test a couple times just save yourself some time and hassle and create a short batch file for this. 9600. Uncheck Do not display the value in the Configuration Manager console. Because of the way our collection environment shakes out, it’s impossible to create a new collection for my new variables without causing undesirable changes in everyone’s workflow. 1 and the correct version of DISM is 6. With MDT integration in ConfigMgr 2007 you have the best of both worlds. mdt 2012 osdcomputername variables

fuzjzmpvyb grh, 0mbrwjcokayi, xszvycqptgenk, nav7ryan1ejpczzl, 041tmy i, qn f0v ljvp,